home SMT-systems division Harima Electronic Materials MS Series

Harima: Electronic Materials MS Series

Specifications
Items Representative Values Test Methods, Remarks
Metal Article Number 31 32 38 37 33 83  
Metal Type Sn 96.5% 93.0% 92.0% 88.0% 91.4% 89.0%  
Ag 3.0% 3.5% 3.5% 3.5% 3.2%    
In   3.0% 4.0% 8.0% 2.7%    
Bi   0.5% 0.5% 0.5% 2.7% 3.0%  
Cu 0.5%            
Zn           8.0%  
Melting point (°C) 219 214 211 206 210 199  
Specific gravity 7.4 7.4 7.4 7.5 7.5 7.3  
Intensity kgf/mm2 3.6 5.1 5.2 6.5 7.8 7.1  
Elongation (%) 38 33 32 30 17 23  
Flux type LF4 LF3 FH1 LF3 LF3 LZ1  
Flux content(%) 12.0 10.7 12.0 10.7 10.7 13.0 JIS Z 3197
Dryness Chalk powder can be removed easily JIS Z 3197
Halide content(%) 0.20 0.20 0.30 0.20 0.20 0.20 JIS Z 3197
Corrosiveness (Copper board) Accepted JIS Z 3197
Resistivity of water extract (ohm.cm) 1 X 105 or more JIS Z 3197
Surface insulation resistance(ohm) 1 X 108 or more JIS Z 3197
Migration test ohm 1 X 1011 or more JIS Z 3197
Visual check
with microscope
No corrosion, no migration JIS Z 3197
Spreading rate (%) 80 or more JIS Z 3197
Particle shape Sphere  
Powder size (µm) 10 ~ 50  
Viscosity (Pa.s) 160 200 200 200 200 200 Malcolm viscometer PCU-2type
Min. pitch of printing 0.25mm The minimum interval causing no bridge after 25 continuous printing
Tackiness force 100gf or more Measured by RESCA Tackiness tester, after exposing 24hrs
Slump test 0.2mm or under JIS Z 3197
Solder ball test At room temperature 50µm or more (0 balls) and 10 to 49µm (10 balls) Observation with microscope X50 after storing at 25°C for 72 hours, printing 6.25ø and reflow.
Change in characteristic with time when the paste is left at room temperature Viscosity Within ± 10% of the change rate from the initial value Malcolm PUC-2 type at 25°C measurement after 14 days
Viscosity recovery rate 75% or more Malcolm PUC-2 type at 25°C measurement after 14 days
Ball 50µm or more (0 balls) and 10 to 49µm (20 balls) Observation with microscope X50 after printing 6.25ø and reflow using viscosity tested oaste.
Change in characteristic with time when the paste is left in cold refrigerator Viscosity Within ± 10% of the change rate from the initial value Malcolm PUC-2 type at 5°C measurement after 90 days
Viscosity recovery rate 75% or more Malcolm PUC-2 type at 5°C measurement after 90 days
Ball 50µm or more (0 balls) and 10 to 49µm (20 balls) Observation with microscope X50 after printing 6.25ø and reflow using viscosity tested oaste.
Viscosity qualities after forced stirs due to 5-time continuous auto measurement Within ± 10% of the change rate from the initial value 5-time continuous measurement with the Malcolm viscometer